Telecom Enclosure

IP55 Enclosures – Free Cooling

Air-based free cooling enclosures are systems used in Telecom, Smart city , Electrical and other IT Infrastructure to maintain optimal temperatures without relying heavily on traditional air conditioning systems. Instead of using compressors and refrigerants, these enclosures leverage outside air to cool the internal space, reducing energy consumption and operating costs.

We do analyze the thermal as per the customer needs and host products variant to cool the solution ranging from 100 W to 4000 W of heat load equipment currently with the Free cooling solution.

Key Components:

  • Air Intake and Exhaust Vents: Allows outside air to flow into and out of the enclosure, facilitating natural cooling.
  • Filters: Ensure that incoming air is free from dust, debris, and other contaminants.
  • Fans: Assist in controlling the flow of air, ensuring proper circulation inside the enclosure.
  • Temperature Sensors: Monitor the internal environment to ensure that conditions remain within safe operating parameters.
  • Control System: Manages the operation of fans, vents, and other components based on real-time data from sensors.

Benefits:

  • Energy Efficiency: Reduces the need for traditional air conditioning, cutting down on energy consumption.
  • Lower Operating Costs: With less reliance on compressors and refrigerants, operating costs are reduced.
  • Environmental Impact: Lower energy use translates to a smaller carbon footprint.

Applications:
  • Telecom
  • Industrial Enclosure
  • Smart cities
  • Safe City Surveillance Projects
  • City Wi-Fi Projects
  • Solar
  • Fibre
  • ITMS-RLVDS-SVDS
  • Electrical enclosures
Technical Data:
Environmental Protection Class IP55
Operating Temperature -5°C to +48°C
Storage Temperature -25°C to +60°C
Earthquake Zone 4 Compliant
Mechanical Construction GI Steel / SS / Aluminium
Surface Powder-coated RAL as per customer preference
Internal Space 3U to 40U
Locking System 4- Point Locking System
Doors 1 Door with Door stopper
Cable Entry Via Cable Glands/ multi-hole system
Weight 25 Kg
Temperature Cooling System Free air-Cooling System
Cooling Capacity 100 W to 4000 W
Sensors Sensors Included Door Alarm Contact, Temperature Sensor, Fan Failure, CCTV(Optional)

SRK Tele Energy India Pvt Ltd.

Unit No. 609-611, Tower C,
Unitech Business Zone,
Sector 50, Gurgaon-122018,
Haryana-INDIA

 

Connect Us
: contact@flexsol.in
: (091) 124-4290477
   

Our Solutions

©COPYRIGHT 2024. ALL RIGHTS RESERVED.